PM 60, Pulse Oximeter
PM-60 is a miniature, lightweight device capable of spot-check and continuous monitoring of SpO2 and pulse rate.
Spot Check Mode
- auto-standby and power off during the idle status
- auto-increase the patients IDs
- non-alarm setting for “sensor off“ occasion 1-99 IDs for maximum 4,000 sets of measurements
Continuous monitoring mode
- regular alarm handing
- enable to input patient ID manually
- view SpO2 waveform for maximum 96 hours trend
Description
PM-60 is a miniature, lightweight device capable of spot-check and continuous monitoring of SpO2 and pulse rate. You determine the capabilities and performance, depending on the operational mode you choose. For simple vital signs checks, spot-check mode offers basic functions including auto-assign of patient IDs, alarm suppression state and auto-standby and power-off features. For longer-term monitoring, continuous mode offers manual entry of unique patient IDs, alarm management and pleth waveform display. If pulse oximetry varies from day to day, or perhaps hour to hour, PM-60 is ideal as your device of choice.
· Suitable for adult, Pediatrics, and neonatal patients
· Performs SpO2 and pulse rate measurement in either spot-check or continuous mode
· Miniature design offers an impressive lightweight device, making it easy to use on the go
· 2.4″ color LCD prominently displays SpO2 and pulse rate readings
· Variable screen brightness allows you to alter the intensity of the LCD and conserve battery power
· Adjustable visual and audible alarms: you can choose whether to show SpO2 and pulse rate alarm limits on the LCD
· In continuous mode, memory supports storage of 96 hours of trended data for a single patient
· In spot-check mode, memory supports storage of 4,000 sets of data for a maximum of 99 patient IDs
· Export real-time patient data to a PC using infrared technology
· Choose from either lithium ion or AA alkaline batteries depending on your run-time needs
· Automatic standby mode and selectable auto-shutdown mode assist in conserving battery power
PM – 60
Plus Oximeter
Technical Specifications
Safety
Meet the requirements of IEC60601 series, (for 3 pieces)36 hours for CE marking according to MDD93/42/EEC
Type of Protection | Class II with internal electric power supply |
Degree of Protection | BF (defibrillation proof ) |
Protection Against Ingress of Liquid | IPX2 |
Dimension and Weight
Dimension | 55(W)X120(H)X30(D)mm |
Weight | Maximum weight 300g 3-level audible and visual alarm (With battery) |
Operation Environment
Temperature | 0~40℃ |
Humidity | 15~95%(non-condensing) |
Storage Environment
Temperature | -20℃~ +60℃ |
Humidity | 10% ~ 95% Alarm range 50~100% (Non-condensing) |
Performance Specifications
Display | 2.4″ color TFT |
Resolution | 320×240 |
Multi displays selectable | Standard screen display Waveform display |
Trace | 1 plethysmogram waveform |
Indicator | Alarm indicator light Power indicator light Pulse tone Alarm sound Button tones |
Interface | One dual-purpose socket for
connecting SpO2 sensor and communication cable. |
IR interface | Infrared link allows downloading realtime patient data to computer |
DC Power interface | Charger stand for Li-ion battery |
DC Power Requirements | Input voltage 5V DC Power 1.2A |
Battery |
Li-ion Battery
2 hours for charging;24 hours for continuous working AA batteries (for 3 pieces)36 hours for continuous working |
Trend memory |
Monitoring mode
Resolution : 2s Maximum time : 96 h Spot – check mode Review of up to 4,000 data; Measure up to 99 patients |
Alarm | User-adjustable High and Low limits
3-level audible and visual alarm |
For detailed specifications refer to the Product Brochure.
Mindray
PM 60